MREM 82 MTM
Ordering Code: 53482093 | EAN: 8594223280575
MREM 82 MTM, MREM 82 MTMVR
Reader module, 13,56 MHz & 125 kHz. Designed for CAME MTM modular entry panels
The reder modul MREM 82 MTM (dual reader 13,56 MHz a 125 kHz) with an embedded single door controller are designed for connection to the RS 485 bus of the APS mini Plus access control system, or for standalone operation.
For two-sided door inspection, the module is equipped with an interface that allows the connection of an input RFID reader with a Wiegand output.
It is possible to connect up to 32 reader modules MREM 82 MTM to a single line of the APS mini Plus system. In effect the number of lines is not limited.
The module contains a switching element for the lock.
The reader is designed for installation in CAME MTM and MTM/VR (antivandal) modular entry panels where they occupy one module space.
With this reader module you can use NFC and mobile app TF Mobile ID for identification.
Product variants
Read: Dual (13,56 MHz & 125 kHz), MF (13,56 MHz), EM (125 kHz.
Installation:MTM - modular panel CAME MTM, MTMVR - modular panel MTM/VR (antivandal)
Download
- Manual, PDF document, 1,75 MB
- Conformity declaration, PDF document, 57 kB
Mechanical parameters | ||
---|---|---|
Weight (netto) | 0,122 kg | |
Operating temperature | -25°C ÷ +70°C | |
Humidity | Max. 95%, non-condensing | |
Housing | IP 54, IK 07 | |
Cable length | 0.5 m | |
Environment | Outdoor equipment - general | |
Color | Silver | |
Surface | Plastic | |
Body | Plastic | |
Painted steel sheet and brushed aluminum | ||
Dimensions | 137,5x136x34 mm |
Technical features | ||
---|---|---|
Supply voltage | 8 ÷ 28 VDC | |
Current demand | Typical | 75 mA (8V); 53 mA (12V); 30mA (24V) |
Maximal | 106 mA (8V); 73 mA (12V); 42mA (24V) | |
Lock switching element | NFET, open drain | |
Version by operating frequency | DUAL | 13,56 MHz and 125 kHz |
ID technologie | MIFARE® Classic®, DESFire®, NFC / EM MARIN | |
Typical reading range | 3 - 5 cm | |
Real time clock | Yes, with self backup for 24 hrs. | |
Memory | ID media | 2,000 ID |
Events | 3,500 | |
Time schedules | 64 | |
Communication interface | RS 485 for system BUS | |
WIEGAND input |