MWGD 46.IP
53446501
Dual door controller, 2x wiegand, 2x Aperio, 4x IN, 4x OUT, 2x RS485, Ethernet, DIN rail mounting, 2x 2,200 events
The MWGD 46.IP dual WIEGAND door controllers are designed for connection of one or two readers, biometric sensors and similar devices with a WIEGAND output and/or one or two APERIO wireless locks to the RS 485 bus of the APS mini Plus access control system, or for standalone operation. It is possible to connect up to 16 MWGD 46.IP door modules to a single communication line of the APS mini Plus system, each occupying 2 successive addresses. These modules may be combined with other APS mini Plus reader modules on the communication line; however the total number of addresses on the line cannot exceed 32. In effect the number of lines is not limited.
The door controller can serve one door with IN and OUT readers or two doors with IN readers.
The module is equipped with an Ethernet connector for direct connection to a network
The door modules are delivered inside a cover for DIN rail mounting, where they occupy a width of 6 modules.
Download
3D presentation
Weight | 0.250 kg | |
Operating temperature | -10°C ÷ +40°C | |
Humidity | Max. 75%, non-condensing | |
Environment | Indoor | |
Dimensions | 6 DIN units, low profile |
Technical features | ||
---|---|---|
Supply voltage | 8 ÷ 28 VDC | |
Current demand | Typical | 140 mA |
Maximal | 230 mA | |
Real time clock | Yes, with self backup for 12 hrs. | |
Memory | ID media | 2x 2,000 ID |
Events | 2x 2,200 | |
Time schedules | 64 | |
Communication interface | RS 485 for system BUS | |
Ethernet | ||
APERIO wireless locks interface | RS 485 for APERIO BUS | |
Number of APERIO locks supported | 2 APERIO wireless locks |